OBTEN ENVIO GRATIS A PARTIR DE 5,000
Agotado

KRAMER BCLS-31 CAT 6A U/UTP 23AWG 650MHz Bulk Cable — Low Smoke & Halogen Free

$20,942.99 $25,812.20
Compartir

Kramer’s BCLS−31 is a high−performance CAT6A U/UTP cable designed for IT, LAN and Ethernet installations. It is constructed with four pairs of 23AWG solid bare copper conductors with a cross filler in an LSZH jacket with internal rip cord and sequential markings every meter and packed on a fumigated plywood reel. The unique zigzag jacket design provides excellent performance of “six around one” bundle transmission. BCLS−31 cable exceeds CAT 6A specifications to provide additional performance and bandwidth beyond the basic standard. High–Performance Single Cable Transmission. Zigzag Jacket Design — Provides excellent performance of six around one bundle transmission. Round & Smooth Jacket without Twisted Stripe. High–Quality Safety Properties. Sweep Frequency up to 650MHz. Length — Available in wooden drums of 500m (1640ft).

Applications Structure cabling for horizontal and building backbone cable IT, LAN and Ethernet installations Ideal for 10GbE and and legacy speeds applications IEEE 802.3af (PoE) / IEEE 802.3at (PoE+)

Configurations Model Description Length Resolution Price BCLS–31YL–5 CAT 6A U/UTP LSZH Cable — Yellow 305.00m (1000ft)

CONSTRUCTION Conductor: 4 pairs of 23AWG solid bare copper Insulation: Polyolefin (PO) Insulation: blue & white, orange & white, green & white, brown & white Twist: Left–hand Assembly: Left hand direction Rip Cord: Polyester multi–yarn Jacket: Low smoke zero halogen (LSZH), yellow (Pantone 116C) Filler Polyolefin (PO) DIAMETERS Jacket: Diameter: 8.3 ±0.2mm Jacket: thickness: 1.10 ±0.01mm Insulation: Blue & white: 1.17 ± 0.02mm Insulation: Orange & white: 1.12 ± 0.02mm Insulation: Green & white: 1.15 ± 0.02mm Insulation: Brown & white: 1.10 ± 0.02mm ELECTRICAL Temperature & Voltage Rating: 60°C @300V Spark Test: 2.5kV DC AC Leakage Current: ≤10mA (1.5kV AC) through overall jacket Conductor DC Resistance: ≤9.38Ω /100m Resistance Unbalance: ≤5% Dielectric Strength: 1.5kV AC for 2sec Insulation Resistance: ≥5000MΩ /m Mutual Capacitance: ≤5.6nF /100m Capacitance Unbalance: ≤330pF /100m pair–to–ground Characteristic Impedance: 100±15Ω @1~100MHz Coupling Attenuation: ≤55dB @30MHz, ≤41dB @500MHz USAGE AND ENVIRONMENTAL Cable Cold Bend: –20°C for 4hr Insulation Tensile Strength: 2400 PSI min. (1.69kg/m,2) NVP: 67% Temperature Range: Storage & shipping: — 20°C to 60°C Temperature Range: installation: 0°C to 60°C Temperature Range: operation: — 20°C to 60°C Minimum Bending Radius: ≥4 times of overall diameter Maximum Pulling Tension: ≤110N REGULATORY PERFORMANCE ANSI/TIA-568-C.2 (2009): Balanced Twisted–Pair Telecommunications Cabling and Components Standards ISO/IEC 11801 (Edition 2.2): Information technology — Generic cabling for customer premises IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications — Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz — Horizontal floor wiring — Sectional specification EN 50288-6-1:2013: Multi–element metallic cables used in analogue and digital communication and control — Part 6–1: Sectional specification for unscreened cables characterized up to 250MHz — Horizontal and building backbone cables REGULATORY SAFETY EN 50173-1:2011: Information technology — Generic cabling systems — Part 1: General requirements IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions — Part 1–2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1kW pre–mixed flame IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions IEC 60754-2: Test on gases evolved during combustion of materials from cables

DC AC: Leakage Current: ≤10mA (1.5kV AC) through overall jacket Conductor DC Resistance: ≤9.38Ω /100m Resistance Unbalance: ≤5% Dielectric Strength: 1.5kV AC for 2sec Insulation Resistance: ≥5000MΩ /m Mutual Capacitance: ≤5.6nF /100m Capacitance Unbalance: ≤330pF /100m pair–to–ground Characteristic Impedance: 100±15Ω @1~100MHz Coupling Attenuation: ≤55dB @30MHz, ≤41dB @500MHz

ND ENVIRONMENTAL: Cable Cold Bend: –20°C for 4hr Insulation Tensile Strength: 2400 PSI min. (1.69kg/m,2) NVP: 67% Temperature Range: Storage & shipping: — 20°C to 60°C Temperature Range: installation: 0°C to 60°C Temperature Range: operation: — 20°C to 60°C Minimum Bending Radius: ≥4 times of overall diameter Maximum Pulling Tension: ≤110N

CE ANSI/TIA-568-C.2 (2009): Balanced Twisted–Pair Telecommunications Cabling and Components Standards ISO/IEC 11801 (Edition 2.2): Information technology — Generic cabling for customer premises IEC 61156-5 (Edition 2.0): Multicore and symmetrical pair/quad cables for digital communications — Part 5: Symmetrical pair/quad cables with transmission characteristics up to 1000 MHz — Horizontal floor wiring — Sectional specification EN 50288-6-1:2013: Multi–element metallic cables used in analogue and digital communication and control — Part 6–1: Sectional specification for unscreened cables characterized up to 250MHz — Horizontal and building backbone cables

TY EN 50173-1: 2011: Information technology — Generic cabling systems — Part 1: General requirements IEC 60332-1-2: Tests on electric and optical fiber cables under fire conditions — Part 1–2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1kW pre–mixed flame IEC 61034-1 / 61034-2: Measurement of smoke density of cables burning under defined conditions IEC 60754-2: Test on gases evolved during combustion of materials from cables