Out of stock

KRAMER FC-132ETH 32–port Serial Control Gateway and Advanced Serial Communication Matrix

$2029.20 USD $2501.22 USD
Share

The FC−132ETH is an advanced Ethernet control gateway and serial communication matrix, capable of plug and play deployment over a customer Ethernet LAN. Serving as an advanced serial communication matrix, the FC−132ETH has 32 RS−232 and one RS−232/RS−485 output ports. Serial communication data is switchable to one or more of the eight RS−232 input ports. This can be done according to local control of panel buttons or RS−232 control port, or remote control via Ethernet port control protocol or web−page browsing. Depending on matrix routing, one−to−one bidirectional or one−to−many unidirectional serial switched communication is supported. Serving as a control gateway, FC−132ETH is capable of remote bidirectional control of customer−controlled devices serially connected to its 32 RS−232 and one RS−232/RS−485 input ports. Multiple control clients can be IP−connected to the FC−132ETH control gateway for concurrent control of two RS−232 or RS−485 controllable devices, such as AV scalers, video displays, and audio amplifiers. 1 RS–485 or RS–232 Selectable Bi–directional Output Port — Controls a device via bi–directional serial control protocols. 32 Bidirectional RS–232 Output Ports — Control a device via bi–directional serial control protocols. 8 Bidirectional RS–232 Input Ports — Switchable serial communication to one or more of the serial input ports. 4 Panel Buttons & LCD Display — Local panel control of serial matrix ports switching. 1 Panel Take / Lock Button — Local panel switching control or tampering prevention. 1 Bidirectional RS–232 Control Port — Local protocol–based switching control port. 1 Ethernet Control Port — Remote protocol–based control portץ Built–in Web Pages — Remote browser–based control and support. Simultaneous IP Control Communication — With up to 40 IP control clients. Mini USB Port — For firmware upgrades and local technical services. Easy Installation — Plug & play IP auto–setup deployment for simple and cost–reducing installation.

Applications Remote IP control of serial controlled devices K–Touch multi–clients IP room control LAN–based expansion of K–Config control system Conference room presentations Advertising applications Rental and staging

PORTS 1 RS–232/RS–485 selectable and 32 RS–232 serial output ports on 3–pin terminal blocks, 8 RS–232 serial input ports on 3–pin terminal blocks, 1 RS–232 serial control port on a 3–pin terminal block, 1 Ethernet on an RJ–45 connector, 1 mini USB connector for local services SUPPORTED SERIAL PORT BAUD RATES 1200, 2400, 4800, 9600, 19200, 38400, 57600, 15200bps RS-232 COMMUNICATION Transparent up to 115200bps MAXIMUM DATA HANDLING OF DEVICE Up to 310kbps summed on all ports CONTROLS Serial Select button, RS–485 terminator switch, DHCP and Factory Default buttons. Front panel buttons and LCD display, RS–232, Ethernet INDICATORS Power, Ethernet, Serial I/O, and DHCP status LEDs POWER CONSUMPTION 100–240V AC, 50/60Hz, 17VA OPERATING TEMPERATURE 0° to +40°C (32° to 104°F) STORAGE TEMPERATURE –40° to +70°C (–40° to 158°F) HUMIDITY 10% to 90%, RHL non–condensing COOLING Convection ENCLOSURE TYPE Aluminum VIBRATION ISTA 1A in carton (International Safe Transit Association) SAFETY REGULATORY COMPLIANCE CE ENVIRONMENTAL REGULATORY COMPLIANCE Complies with appropriate requirements of RoHs and WEEE INCLUDED ACCESSORIES Power cord, rack mounting brackets OPTIONAL Serial cables: C–D9F/OPEN–3/6/10/15/25/35/50, BC–1T–300M bulk cable Product Dimensions 19" x 7.20 x 1U (43.6cm x 18.30cm x 4.36cm) W, D, H Product Weight 1.7kg (3.7lbs) approx. Shipping Dimensions 55.00cm x 27.60cm x 10.70cm (21.65" x 10.87" x 4.21" ) W, D, H Shipping Weight 2.5kg (5.5lbs) approx.

UD RATES: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 15200bps

S-232 COMMUNICATION: Transparent up to 115200bps

OF DEVICE: Up to 310kbps summed on all ports CONTROLS Serial Select button, RS–485 terminator switch, DHCP and Factory Default buttons. Front panel buttons and LCD display, RS–232, Ethernet INDICATORS Power, Ethernet, Serial I/O, and DHCP status LEDs

ER CONSUMPTION: 100–240V AC, 50/60Hz, 17

NG TEMPERATURE: 0° to +40°C (32° to 104°F)

GE TEMPERATURE: –40° to +70°C (–40° to 158°F) HUMIDITY 10% to 90%, RHL non–condensing COOLING Convection

RE TYPE: Aluminum

ON ISTA: 1A in carton (International Safe Transit Association)

RY COMPLIANCE: Complies with appropriate requirements of RoHs and

ED ACCESSORIES: Power cord, rack mounting brackets OPTIONAL Serial cables: C–D9F/OPEN–3/6/10/15/25/35/50, BC–1T–300M bulk cable Product Dimensions 19" x 7.20 x 1U (43.6cm x 18.30cm x 4.36cm) W, D, H Product Weight 1.7kg (3.7lbs) approx. Shipping Dimensions 55.00cm x 27.60cm x 10.70cm (21.65" x 10.87" x 4.21" ) W, D, H Shipping Weight 2.5kg (5.5lbs) approx.

K–Config Configuration Software Version 3.6.13.0 Configuration software for Room Controllers. Please refer to Release Notes for Known Issues, and note K–Config is not backward compatible with RC–SV Configuration software. By downloading this software you agree to the EULA K–Upload Version 1.1.36.0 By downloading this software you agree to the EULA KLAN Configurator Software Version 1.0.5.0 (beta)

FC–132ETH Firmware Version 2.19.62788 To upgrade the firmware, use USB or Ethernet connection and K–Upload software. Before connecting to the Ethernet on the device, set K–Upload to UDP and default port 50000.

Download DXF (BLOCK DIAGRAM)

  • K–LAN Configurator Guide
  • FC–132ETH User Manual
  • K–UPLOAD User Manual
  • Version 1.0.5.0 (beta)
  • FC–132ETH Release Notes
  • Download DXF (BLOCK DIAGRAM)
  • DOCUMENTATION K–LAN Configurator Guide FC–132ETH User Manual K–UPLOAD User Manual
  • SOFTWARE K–Config Configuration Software Version 3.6.13.0 Configuration software for Room Controllers. Please refer to Release Notes for Known Issues, and note K–Config is not backward compatible with RC–SV Configuration software. By downloading this software you agree to the EULA K–Upload Version 1.1.36.0 By downloading this software you agree to the EULA KLAN Configurator Software Version 1.0.5.0 (beta)
  • FIRMWARE FC–132ETH Firmware Version 2.19.62788 To upgrade the firmware, use USB or Ethernet connection and K–Upload software. Before connecting to the Ethernet on the device, set K–Upload to UDP and default port 50000.
  • RELEASE NOTES FC–132ETH Release Notes
  • [H2] PRODUCT DXF (BLOCK DIAGRAM)